● DSP digital control technology

● Active power factor correction (APFC), input power factor up to 0.99

● Output power factor 0.9

● Cold start

● Dual input

● Wide input voltage range (190 V ~ 485 V)

● Auto sensing frequency

● 50 / 60 Hz frequency conversion mode

● Work efficiency up to 98% in ECO mode

● Auto control fan speed when loads varies

● Auto power ON/OFF according to the load capacity set by users

● Flexible battery configuration for using 14/16/18/20 pcs batteries

● Compact internal layout, miniaturized the complete unit for small footprint

● LCD+LED display, multi-functional keys operation, friendly human-machine interface

● Powerful background software for parameters configuration and online updating

● Doubling the battery charging speed, 90% capacity restored in 4 hours (standard model UPS

● Linear derating in low voltage input, reducing battery discharging times, extending the service life of battery

● Advanced battery management (ABM), automatic floating / equalizing charge control, charger dormancy control

● Configurable switching time from battery mode to mains mode when mains power is restored, reducing the impact on power grid or generator

● Effective software and hardware protection function, powerful self-diagnostic function, abundant historical records

● Standard emergency power off (EPO)

● Standard maintenance bypass

● Standard RS232/USB communication port

● Optional RS485 / SNMP / AS400 communication port and SMS alarms

● Optional N+X redundancy parallel up to 6 units

● Optional battery temperature compensation, EMD environmental sensors


Model Nextwave Giga power 10kva online 3/3
Cabacity 10 KVA / 9 kw
INPUT  
Rated voltage 360 / 380 / 400 / 415 Vac
Voltage Range 277 ~ 485 Vac (no derating);
190 ~ 277 Vac (linear derating between 50% and 100% load)
Rated frequency  50 / 60 Hz (auto-sensing)
Frequency range 40 ~ 70 Hz
Power factor  ≥ 0.99
Bypass voltage range  - 40% ~ +15% (settable)
Total harmonic distortion (THDi)  ≤ 5%
OUTPUT  
Rated voltage 360 / 380 / 400 / 415 Vac (settable)
Voltage regulation  ±1% 
Frequency  45 ~ 55 Hz or 55 ~ 65 Hz (synchronized range); 50 / 60 Hz ± 0.1 Hz (battery mode)
Waveform  Sinusoidal
Power factor  0.9
Total harmonic distortion (THDv) ≤ 2% (linear load), ≤ 5% (non-linear load)
Crest factor  3:1
Overload (Inverter)  102% ~ 125% for 10 min, 125% ~ 150% for 1 min, > 150% for 0.5 s
Overload  102% ~ 125% for 20 min, 125% ~ 150% for 2 min, > 150% for 1 s
BATTERIES  
DC voltage  Standard model: 240 Vdc; Long time model: 192 Vdc (168 / 192 / 216 / 240V optional)
Inbuilt battery (standard model) 20 × 7 Ah
Charging current Long time model: 7 A supplied (additional 7 A is optional) Standard model:  1 A, 2 A, 3.5 A settable
Recharge time Standard model:  90% capacity restored in 4 hours; Long time model: depend on the capacity of battery
SYSTEM  
Efficiency ≥ 93%, ECO mode 98%
Transfer time  0 ms
Protections  Short-circuit, overload, overtemperature, battery low voltage, overvoltage, undervoltage and fan failure
Communications  RS232 (standard), USB / RS485 / dry contacts / SNMP (optional) 
Max. number of parallel connections  6
Communications RS232 (standard), USB / RS485 / dry contacts / SNMP / battery temperature compensation (optional)
Display LCD + LED 
Standards EN 62040-1, EN 62040-2, EN 61000-3-12, EN 61000-3-2, EN 61000-3-11,
IEC 61000-4-2, IEC 61000-4-3, IEC 61000-4-4, IEC 61000-4-5, IEC 61000-4-6, IEC 61000-4-8, IEC 61000-4-11, IEC 61000-2-2
OTHERS  
Operating temperature 0℃ ~ 40℃
Storage temperature -25℃ ~ 55℃ (without batteries)
Relative Humidity 0 ~ 95% (non-condensing)
Altitude ≤ 1000 m, derating 1% for each additional 100 m
IP rating IP 20
Noise level at 1m ≤ 65 dB
Online thermal dissipation 5773 BTU/hr
Dimensions (W×D×H) (mm) 350 × 655 × 732 (H)
Net weight (kg) 155 (S) 
Gross weight (kg)  170(S)