Duct Type Single Sheathed Fiber Optic Cables


  • Loose tube designed.
  • Duct type installation for highly reliable industrial applications.
  • Applicable for outdoor and indoor applications, also it’s designed to protect optical fiber for the unexpected mechanical and environmental conditions.
  • Qualification and acceptance testing are performed to assure the optical cable’s performance and durability in several environments.
  •  Features and Benefits
  • Fiber counts up to 216
  • High tensile strength design
  • Fibers per loose tube 1-12
  • Gel filled cable core for the water resistance
  • Dry core design is also possible for water
  • resistance in customer request
  • Suitable for duct applications
  • Colored fiber for the quick identification
  • UV resistance for the outer Sheath
  • High fiber count to diameter ratio
  • Fully complied with Telcordia GR-20 and TIA/EIA standards
  • Custom designs are available on request

  • Applications
  • Telecommunication applications
  • Video applications
  • Distribution
  • Long Haul Communication and Metropolitan
  • Communication Systems

Cable Weight & Diameter
Item: Duct Type Single Sheathed Fiber Optic Cables

Number of Fiber Fiber per Tube Number of Tube Number of Dummy Tube Nom. Outer Diameter
(mm)
Nom. Cable Weight (Kg/km) Reel Length
(Km)*
4 2 2 4 11,0 100 6
6 2 3 3 11,0 100 6
12 2 6 0 11,0 100 6
24 4 6 0 11,0 100 6
36 6 6 0 11,0 100 6
48 8 6 0 11,0 100 6
60 12 5 1 11,0 100 6
72 12 6 0 11,0 100 6
96 12 8 0 12,5 140 4
144 12 12 0 15,5 195 4
192 12 16 2 15,5 210 4
216 12 18 0 15,5 210 4

Note: Central Strength member is FRP (Fiber Reinforced Plastic), but steel wire is also available on customer request. 
(*) Other delivery length is available


Mechanical & Environmental Characteristics
Parameters

Tensile Strength
IEC 60794-1-2-E1
Max.
Opr.
2.000 N
1.000 N
Bending Radius(mm)
IEC 60794-1-2-E11
Dynamic
Static
20xD
10xD
Crush Resistance
IEC 60794-1-2-E3
--------
--------
2000 N
--------
Impact Resistance
IEC-60794-1-2-E4
--------
--------
50 N
--------
Operation Temperature
IEC 60794-1-2-F1
Installing
Operating
-30 +60 (°C)
-40 +80 (°C)
Water Penetration
IEC 60794-1-2 F5
24 hour, 1 meter No leakage No leakage

Note: Special design for higher than given tensile load also available


Sales Ticket Form